info@redata.com.np
+977-1-5349371/ 5365142

ROCKSEAL 6600P

Heading

ROCKSEAL 6600P

DESCRIPTION

ROCKSEAL 6600P is a two component Polysulphide sealant. It is used for sealing expansion joint sealantwhere large movement is anticipated in concrete construction and for joints between diverse construction materials like glass, aluminum, steel, cladding, glazing, tiling, tanks, internal and water retaining structures. It is used for sealing of expansion joints where there is vehicular traffic (e.g. airports and bridges) or pedestrian traffic. After mixing Resin and Hardener, the polymerization is initiated at room temperature, which proceed further until it is cured.

It has superior joint movement accommodation with strong adhesion to most building material. It is chemically resistance to water oils solvents

TYPICAL CHARACTERISTICS

RESIN

Chemical type Polysulphide
Appearance Flowable Paste
Color Off- white
Viscosity at 30°C, Brookfield DV-II+, Spindle 06, 50,000 – 90,000
speed 50 rpm, cPs, ATM R006 (ISO*2555)  
   
Specific gravity at 300C, ATM* R004 (JIS* K6820) 1.60 – 1.75
   
Flash Point Refer MSDS

HARDENER

Chemical type Manganese Di Oxide Base
Appearance Smooth Paste
Color Brown
Viscosity at 30°C, Brookfield DV-II+, Spindle 06, 8000– 12,000
speed 50 rpm, cPs, ATM R006 (ISO*2555)  
   
Specific gravity at 300C, ATM* R004 (JIS* K6820) 1.65 – 1.80
   
Flash Point Refer MSDS

MIXED ADHESIVE

Mixing ratio R:H (w/w) 92 : 08
Color Grey
Pot life at RT, 500g mix, minutes, ATM R007 100 – 260
Cure time at RT, 500g mix, Hours ATM R364 160 – 360
   
Exothermic observed, 500g mix, °C Below 40
   
Flash Point Refer MSDS
Flow , ATM R016 Flowable

CURING PERFORMANCE

The product will achieve its handling strength after 24 hours at room temperature. Curing Continues for atleast 7 days before full properties are developed.

CURE SCHEDULED

  At 35°C, Days   7  
  At 5°C, weeks   7 – 8  
             
OPERATING PARAMETERS        
           
  Application temperature   5oC to 45oC
  In service temperature   – 40oC to 80oC
PHYSICAL PROPERTIES        
         
  Durometer Hardness, ATM-R019 Shore A 8 – 14  
  (ASTM D2240)      
  Shear Strength, MS to MS ATM R022 kg/cm2 ≥ 3  
  (ASTM D1002)      
  Shear Strength, MS to MS ATM R022 kg/cm2 ≥ 3  
  (ASTM D1002)      
  Shear Strength, MS to MS ATM R022 kg/cm2 ≥ 3  
  (ASTM D1002)      
         
  Tensile strength, ATM R020(ASTM kg/cm2 ≥ 2.5  
  D882)      
         
  Elongation, ATM R020(ASTM D882) % ≥ 450  

DIRECTIONS FOR USE

METHOD OF APPLICATION

The product may be applied to joint between 5 to 50 mm wide. Joints subjected to cyclic movements sho designed for an optimum width/Depth ratio of (W = 2D)

Minimum joint depths are:

5mm for metals, glass and other non – porous surfaces.

10mm for all porous surfaces like brick and concrete.

20mm for trafficked joints and those subject to hydraulic pressures

Hardener is mixed with Resin and stirred gently to get uniform color mix. Prior to the application of the sealant all joint surfaces should be thoroughly cleaned and dried and primed with suitable primer. Primer promotes strong adhesion of the sealant to the surface and is absolutely essential on most surfaces. Primer should be brushed on the sides of the joint. ROCKSEAL 6600P have excellent adhesion of the joint. In order to get maximum adhesion to surface of construction,

STORAGE AND SHELF LIFE

The Resin and Hardener should be stored at a temperature not exceeding. At higher storage temperatures the storage life would decrease sharply. The Resin and the Hardener containers should not be exposed to sunlight to avoid gelation.

Shelf life is 12 months from the date of manufacture in unopened containers PACKING

3680 Gms Resin in 4 liter wide mouth tin container.

320 Gms Hardener in 250 ml plastic cover

PRECAUTIONS

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

DISCLAIMER The above information and details herein are based on the tests conducted & experience on application and usage. The user is advised to carry out the test and take trials to satisfy on the suitability of the products and meeting his requirement considering the prevailing conditions prior to apply/ using it on larger area. As the conditions under which the products are used or transported are beyond our control. We would not hold ourselves responsible on its consequential nonperformance.

Download PDF